globalchange  > 过去全球变化的重建
DOI: 10.1177/0143624419842006
WOS记录号: WOS:000473485700005
论文题名:
Overheating risk in Passivhaus dwellings
作者: Mitchell, Rachel; Natarajan, Sukumar
通讯作者: Natarajan, Sukumar
刊名: BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY
ISSN: 0143-6244
EISSN: 1477-0849
出版年: 2019
卷: 40, 期:4, 页码:446-469
语种: 英语
英文关键词: Chartered Institution of Building Services Engineers TM59 ; overheating ; Passivhaus
WOS关键词: MONITORED PERFORMANCE ; SUMMER
WOS学科分类: Construction & Building Technology
WOS研究方向: Construction & Building Technology
英文摘要:

Highly insulated and airtight homes designed to reduce energy consumption are perceived as having a greater summer overheating risk than less insulated homes. If true, dwellings built to the well-known low-energy Passivhaus (PH) standard could be at greatest risk due to the use of superinsulation, especially as the climate warms. Existing studies are inconclusive and even contradictory, mainly due to small sample sizes. Hence, this paper presents the first large-scale overheating risk analysis of UK Passivhaus dwellings using high-resolution internal temperature data from 82 homes across the UK. Both the Passivhaus and the recently published Chartered Institution of Building Services Engineers TM59 criteria are analysed. Results show that the whole-dwelling Passivhaus standard, which uses a fixed temperature threshold, is met more frequently (83%) than when applied on a room-by-room basis (e.g. only 60% of bedrooms in houses meet the standard). TM59-1A, which uses an adaptive temperature threshold, is easier to meet with 100% of flats and 82% of houses in compliance. However, 55% of bedrooms assessed under TM59-1B fail, with little difference between flats and houses. This is a remarkable finding given that the summers under consideration were either typically mild or cooler than average, and that sleep impairment can significantly affect both physical and mental health. These results suggest that highly insulated dwellings such as Passivhaus should consider overheating in individual rooms, rather than at whole-dwelling level. Analysis should be undertaken throughout the year with particular attention to bedrooms, using either the good-practice PH-5% exceedance threshold which maps well to TM59-1B, or TM59-1B itself.


Citation statistics:
资源类型: 期刊论文
标识符: http://119.78.100.158/handle/2HF3EXSE/141040
Appears in Collections:过去全球变化的重建

Files in This Item:

There are no files associated with this item.


作者单位: Univ Bath, Dept Architecture & Civil Engn, Bath BA2 7AY, Avon, England

Recommended Citation:
Mitchell, Rachel,Natarajan, Sukumar. Overheating risk in Passivhaus dwellings[J]. BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY,2019-01-01,40(4):446-469
Service
Recommend this item
Sava as my favorate item
Show this item's statistics
Export Endnote File
Google Scholar
Similar articles in Google Scholar
[Mitchell, Rachel]'s Articles
[Natarajan, Sukumar]'s Articles
百度学术
Similar articles in Baidu Scholar
[Mitchell, Rachel]'s Articles
[Natarajan, Sukumar]'s Articles
CSDL cross search
Similar articles in CSDL Cross Search
[Mitchell, Rachel]‘s Articles
[Natarajan, Sukumar]‘s Articles
Related Copyright Policies
Null
收藏/分享
所有评论 (0)
暂无评论
 

Items in IR are protected by copyright, with all rights reserved, unless otherwise indicated.