论文题名:
Insulation failure caused by special pollution around industrial environments
作者: Arias Velasquez, Ricardo Manuel
通讯作者: Arias Velasquez, Ricardo Manuel
刊名: ENGINEERING FAILURE ANALYSIS
ISSN: 1350-6307
EISSN: 1873-1961
出版年: 2019
卷: 102, 页码:123-135
语种: 英语
英文关键词: Lime ; Pollution ; Fog ; Insulation
WOS关键词: CORONA DISCHARGE ; TRANSMISSION-LINES ; AUDIBLE NOISE ; SIMULATION
WOS学科分类: Engineering, Mechanical ; Materials Science, Characterization & Testing
WOS研究方向: Engineering ; Materials Science
英文摘要:

In the recently years, the industrial process has increased his production, in this way, the energy consumption has grown significantly with more substations and overhead lines around the industrial plants with lime production. There are many challenges in this kind of industry. One of the main polluting agents is the lime, in a Gold concentrator plant for power substation. The lime is composed primarily of hydroxide, oxides, and their composed. The porcelain is usually used for the insulation between the electrical devices as the circuit breaker, Insulators, current transformers, surge arresters, among others. The insulation has some changes with the climatic change and his manifestation as the moisture, fog, rain and snow. Although the electrical engineering has important advances, about the insulation and maintenance, the insulation failure caused by lime pollution and fog condition has an important relevance, associated to the partial and corona discharge, this condition has been found in the insulation associated to the bus bar Insulators. The main characteristic is the influence of lime and fog, in an area of heavy pollution with high voltage substations. In this research, the partial and corona discharges are described in the section 2, with the electronic devices for the diagnosis and the description of the components for the failure in the insulation, besides, in the section 3 is described the case study with the largest Industrial process in Chile associated to the main substation in 220 kV. In addition, the section 4 has the results and discussion about this phenomenon with the alternatives for assessment and corrections in this environment, accordingly, the results of this research should make available a reference to improve the efficiency of the maintenance and fault diagnosis.


Citation statistics:
资源类型: 期刊论文
标识符: http://119.78.100.158/handle/2HF3EXSE/144955
Appears in Collections:全球变化的国际研究计划

Files in This Item:

There are no files associated with this item.


作者单位: Univ Nacl San Agustin Arequipa, Arequipa, Peru

Recommended Citation:
Arias Velasquez, Ricardo Manuel. Insulation failure caused by special pollution around industrial environments[J]. ENGINEERING FAILURE ANALYSIS,2019-01-01,102:123-135
Service
Recommend this item
Sava as my favorate item
Show this item's statistics
Export Endnote File
Google Scholar
Similar articles in Google Scholar
[Arias Velasquez, Ricardo Manuel]'s Articles
百度学术
Similar articles in Baidu Scholar
[Arias Velasquez, Ricardo Manuel]'s Articles
CSDL cross search
Similar articles in CSDL Cross Search
[Arias Velasquez, Ricardo Manuel]‘s Articles
Related Copyright Policies
Null
收藏/分享
所有评论 (0)
暂无评论
 

Items in IR are protected by copyright, with all rights reserved, unless otherwise indicated.