CO-2/low GWP refrigerants hybrid heat pump water heater system is proposed. This paper analyzes the impact of system components of different C0_2 fractions of the system thermal performance coefficient and pressure conditions, and we obtained the conclusion that mixed refrigerants can reduce the operating pressure of the high pressure side to improve the thermal performance. Considering the environmental impact of proposed comprehensive evaluation system, and gives the recommended target working fluid under different conditions.