DOI: 10.1515/rtuect-2014-0009
论文题名: Performance analysis of air-to-water heat pump in Latvian climate conditions
作者: Kazjonovs J. ; Sipkevics A. ; Jakovics A. ; Dancigs A. ; Bajare D. ; Dancigs L.
刊名: Environmental and Climate Technologies
ISSN: 16915208
出版年: 2014
卷: 14, 期: 1 起始页码: 18
结束页码: 22
语种: 英语
英文关键词: air-to-water heat pump
; Coefficient of performance
; COP
; Heat pump
; Seasonal performance factor
; SPF
Scopus关键词: building
; climate conditions
; electricity supply
; energy use
; European Union
; performance assessment
; pump
; Latvia
; Riga
英文摘要: Strategy of the European Union in efficient energy usage demands to have a higher proportion of renewable energy in the energy market. Since heat pumps are considered to be one of the most efficient heating and cooling systems, they will play an important role in the energy consumption reduction in buildings aimed to meet the target of nearly zero energy buildings set out in the EU Directive 2010/31/EU. Unfortunately, the declared heat pump Coefficient of Performance (COP) corresponds to a certain outdoor temperature (+7 °C), therefore different climate conditions, building characteristics and settings result in different COP values during the year. The aim of this research is to investigate the Seasonal Performance factor (SPF) values of air-to-water heat pump which better characterize the effectiveness of heat pump in a longer selected period of time, especially during the winter season, in different types of residential buildings in Latvian climate conditions. Latvia has four pronounced seasons of near-equal length. Winter starts in mid-December and lasts until mid-March. Latvia is characterized by cold, maritime climate (duration of the average heating period being 203 days, the average outdoor air temperature during the heating period being 0.0 °C, the coldest five-day average temperature being −20.7 °C, the average annual air temperature being +6.2 °C, the daily average relative humidity being 79 %). The first part of this research consists of operational air-towater heat pump energy performance monitoring in different residential buildings during the winter season. The second part of the research takes place under natural conditions in an experimental construction stand which is located in an urban environment in Riga, Latvia. The inner area of this test stand, where air-to-water heat pump performance is analyzed, is 9 m2. The ceiling height is 3 m, all external wall constructions (U = 0.16 W/(m2K)) have ventilated facades. To calculate SPF, the experimental stand is equipped with sensors which provide measurements for electricity consumption and gained heat energy. © 2014, Riga Technical University. All rights reserved.
Citation statistics:
资源类型: 期刊论文
标识符: http://119.78.100.158/handle/2HF3EXSE/67517
Appears in Collections: 气候变化与战略
There are no files associated with this item.
作者单位: Riga Technical University, Latvia; ‘RIKON AC’ Ltd, Latvia; University of Latvia, Latvia
Recommended Citation:
Kazjonovs J.,Sipkevics A.,Jakovics A.,et al. Performance analysis of air-to-water heat pump in Latvian climate conditions[J]. Environmental and Climate Technologies,2014-01-01,14(1)