DOI: 10.1016/j.atmosenv.2018.03.022
Scopus记录号: 2-s2.0-85044150235
论文题名: Outdoor air 1,3-butadiene monitoring: Comparison of performance of Radiello® passive samplers and active multi-sorbent bed tubes
作者: Gallego E ; , Teixidor P ; , Roca F ; J ; , Perales J ; F ; , Gadea E
刊名: Atmospheric Environment
ISSN: 0168-2563
EISSN: 1573-515X
出版年: 2018
卷: 182 起始页码: 9
结束页码: 16
语种: 英语
英文关键词: 1,3-Butadiene
; Active sampling
; Outdoor air quality
; Passive sampling
; TD-GC/MS
Scopus关键词: Air quality
; Desorption
; Gas chromatography
; Ozone
; Quality assurance
; Quality control
; Sorbents
; Sorption
; 1 ,3-butadiene
; Active sampling
; Outdoor air qualities
; Passive sampling
; Td-gc/ms
; Tubes (components)
Scopus学科分类: Environmental Science: Water Science and Technology
; Earth and Planetary Sciences: Earth-Surface Processes
; Environmental Science: Environmental Chemistry
英文摘要: A comparison was made between the relative performance of active and passive sampling methods for the analysis of 1,3-butadiene in outdoor air. Active and passive sampling was conducted using multi-sorbent bed tubes (Carbotrap, Carbopack X, Carboxen 569) and RAD141 Radiello® diffusive samplers (filled with Carbopack X), respectively. Daily duplicate samples of multi-sorbent bed tubes were taken over a period of 14 days (9 + 5 days) at El Morell (Tarragona, Spain), near the petrochemical area. As 1,3-butadiene is a reactive pollutant and can be rapidly oxidized, half of the samplers were equipped with ozone scrubbers. Samples consisted in two tubes connected in series (front and back) to allow the determination of breakthrough. Quadruplicate samples of Radiello® tubes were taken over a period of 14 days (9 days and 5 days), too. During those days, ozone concentration was measured using RAD172 Radiello® samplers. In addition to this, daily duplicate samples of multi-sorbent bed tubes were taken in the city of Barcelona over a period of 8 days. Simultaneously, 4 samples of Radiello® tubes were exposed to outdoor air. Sampling was done throughout June and July 2017. Analysis was performed by thermal desorption coupled with gas chromatography/mass spectrometry. Analytical performance of the two sampling methods was evaluated by describing several quality assurance parameters, with results showing that performances are quite similar. They display low detection limits, good precision, linearity and desorption efficiency, low levels of blank values, and low breakthrough for multi-sorbent bed tubes. However, Radiello® samplers were not able to uptake episodic 1,3-butadiene high concentrations, leading to underestimation of real values. Hence, we can conclude that Radiello® samplers can be used for baseline 1,3-butadiene levels whereas multi-sorbent bed tubes would be advisable when relevant episodes are expected. © 2018 Elsevier Ltd
Citation statistics:
资源类型: 期刊论文
标识符: http://119.78.100.158/handle/2HF3EXSE/82867
Appears in Collections: 气候变化事实与影响
There are no files associated with this item.
作者单位: Laboratori del Centre de Medi Ambient, Escola Tècnica Superior d'Enginyeria Industrial de Barcelona (ETSEIB), Universitat Politècnica de Catalunya (LCMA-UPC), Avda. Diagonal, 647, Barcelona, Spain; Centres Científics i Tecnològics, Universitat de Barcelona (CCiTUB), Lluís Solé Sabarís 1-3, Barcelona, Spain; Centro Nacional de Condiciones de Trabajo, CNCT-INSSBT, Dulcet 2-10, Barcelona, Spain
Recommended Citation:
Gallego E,, Teixidor P,, Roca F,et al. Outdoor air 1,3-butadiene monitoring: Comparison of performance of Radiello® passive samplers and active multi-sorbent bed tubes[J]. Atmospheric Environment,2018-01-01,182